Daily report and daily request, weekly Target, Monthly Target, Years Target
Order equipment, review material and material control, Control subcontractors Inspection checklist report,
Setting Sub contractor Time to work on time Form work check
Alinement, Spec. Level , Spec. Dimension , Spec.
Rigidity and bracing, Sealing against grout leak, Cleanliness, Form oil,
Chamfers and grooves, Drop area, opening, Comment and Actual, After Before and casting concrete, Reinforcement check
Grade of bars & sizes, Spec. No. of bars, Spec.
Spacing of bars and links, Spec. Tying & rigidity
Lapping, anchorage & Hook, Spec: 40d, 50d = Cover, spacer blocks , Spec.
Cleanliness from loose rust scale oil etc., Any other starter bars,
Other Embedded Elements checkSize & dimenstion,
Spec. Position & quantity, Spec. Anchorage rod & length Spec. Welding & fixness, Post tension cables & duct
Fabrication form work footing column, install re-bar and formwork, check
Before and After casting concrete
Earth work and excavation check Authority check
Permit to commence work, Approved dumping yard
Pre-Excavation,
Survey points & temp benchmarks Existing underground utilities, Underground water table Temporary retaining wall Dewatering system
Fire rated wall work and Painting work.
Install frame steel shutter & door
Metal sheet & Frame siding wall and Check a line ments
Check Excavation and Backfilling final
Addition work permit and Plant Maintenance Factory
Navigation Tower Construction Steel Structure Work Column Truss ckeck the material and transport and Plan for installation check size of work to be sand Drawing check plan on how many days to install
Tighten nut and inspection final check
Slip form work check the size for installation and material re-bar check for casing concrete Before casing concrete and after casing concrete check vertical Every time for slip up and casing concrete
Addition work Renovate factory and Maintenance work
Coordinates submit accomplishment reports to Project Manager
Coordinate with owner consultant representative inspection
Control Contractors based on the specifications and Plans given by the company
Inspection Critical appraisal involving examination, measurement, testing, gauging, and comparison of
materials or items, in order to determine if the material or item is in proper condition and quantity,
and if it conforms to the applicable or specified requirements.
ITR (Inspection and Test Report) a formal written report detailing the results of an inspection organized in
a narrative, graphic, or tabular form, identified for each QC Code Once signed by the involved
parties it becomes a Certificate. It includes also the traceability versus the inspected Item
ITP (Inspection and Test Plan) Specific Section(s) of QCP that identify and define Inspection sequences. It is
prepared in accordance with all the applicable contractual, engineering and Supplier’s provisions and
requirements. The ITP(s) provide references to applicable procedures, acceptance criteria, documentation,
quality records and inspection attendance to be performed, in chronological order, from initial inspection,
throughout final inspections and mechanical completion. The ITP(s) provide reference for the
Inspection Forms to be used
Building & Factory work: Survey mark up the location and leveling are complied with IFC drawing,
Inspection Pile driving works, Prestressed Concrete pile, Bored pile concrete spun pile
Inspection Static pile load Test, Dynamic Load Test, Seismic Test.
Casting lean concrete to protect slab rebar dirty and make line for marking border (If require)
Install reinforcement bar which are complied with IFC drawing, Recheck reinforcement steel bar,
dimension and stability of formwork before concrete placing by suitable machine.
In case of lifting works have to support for concrete placing, lifting works shall be following the procedure in
clause, make it is QC Inspection shall be approved in accordance with specific ITP.
Finishing inspection Building: Inspection Masonry Works and Vertical & horizontal Lintel, Inspection Walls
Alignment before Plastering works, Inspection Door & windows Installation and Final Inspection,
Inspection Painting Application & Ambient Condition Surface, Inspection Grade of bars & size. Spec. of bars.
Spec. Spacing of bars and links, Spec Tying & rigidity. Lapping, Spec. 40d, 50d = Cover, spacer blocks,
Concrete Work Field inspection: Check before concrete delivery/placement: - poured lean concrete status -
formwork & reinforcement vertical and horizontal levels - steel bars - anchor bolts - embedment, pockets,
holes, joints, chamfer, mesh, etc. - quantity, diameter/size, shape - locations (Coordinates/elevation) concrete
cover thickness Subgrade / Grade Inspection Report Before Laying Fill Material Asphalt Concrete Placement
Finishing inspection Road: Check completeness of concrete roads, parking areas and paving works
compliance with Project requirements: - surface texture - vertical and horizontal levels, slope, dimensions
sealed joints Inspection Report on Final Course of Completed Asphalt or Concrete Roads, Parking Areas and
Paving Works
Structural Field inspection: Check on formation level before structural concrete delivery/placement formation
grade status, slope - polyethylene sheet - formwork & vertical and horizontal levels - embedment, joints
chamfer, mesh etc. Inspection Report Before Structural Concrete Pouring and Grout Placement
Metal sheet & Frame siding wall and Checking, Alinements, Before installation’s
Pit Work: Survey mark up the location and leveling are complied with IFC drawing,
Inspection Pile driving works, check before concrete delivery/placement: - poured lean concrete status -
formwork & reinforcement vertical and horizontal levels - steel bars - anchor bolts - embedment
Watertight Test: Water tightness Test of Main Basins, Inspection after concrete protective coating application
check the system (pipes and pit / manholes / catch basins, etc.) watertight fulfillment
Finishing inspection: check completeness of all kind of Project sewer/Drain system, PIT, manholes and catch
basins internal final cleaning - installed steps, frames and cover slab, grating and hermetic cove thickness - etc.
Fireproofing Field inspection: Check before fireproofing material delivery/placement - formwork (if any)
reinforcement vertical and horizontal levels - wire mesh, embedment, joints provisions etc.- quantity,
diameter/size, shape, dimensions, locations - cover thickness - etc.
Main grouting: Checks before delivery & placement of mixed grout: - status of chipped & soaked prepared
foundation - surface under erected base plate or equipment, formwork vertical & horizontal levels, joints,
shape, - clearance between base plate and foundation top, chamfers, etc.- Cement Material for Grouting -
surface texture -vertical and horizontal levels, slope, dimensions - sealed joints
Promote job site safety, encourage safe work practices and rectify job site hazards immediately.
Regularly participation in HSE meetings, daily jobs site walks, conducts toolbox talks and keep records.
Implement construction work processes, project procedures and instructions within assigned operations.
Comply with the contract requirements or is being performed outside of the contract scope.
Attend subcontract/cost awareness sessions and understand the Responsibility matrices,
BOQ & preambles of subcontract.
Provide solutions to subcontractor’s problems in order to achieve the successful execution of the project.
Verify that the material handed over to the Subcontractor is controlled, preserved and
issued for the intended purpose.
Closely monitor additional work of Site Instruction until work is completed and to inform
PROFESSIONAL EXPERIENCE
September 2020 – June 2021
MHI Power Project (Thailand)Co., Ltd.
Civil inspector, Civil Supervisor
Project. Gulf Sriracha Power Plant Project (2500MW) Chonburi, Thailand
Plant Location. Sriracha Chonburi (THAILAND)
Coordinates and submit accomplishment reports to the Project Manager and Consultant Representative
ITP Inspection Critical appraisal involving examination, measurement, testing, gauging, and comparison of
materials or items, in order to determine if the material or item is in proper condition and quantity,
and if it conforms to the applicable or specified requirements.
Concrete Work Field inspection: Check before concrete delivery/placement: - poured lean concrete status -
formwork & reinforcement vertical and horizontal levels - steel bars - anchor bolts - embedment, pockets,
holes, joints, chamfer, mesh, etc. - quantity, diameter/size, shape - locations (Coordinates/elevation) concrete
cover thickness Subgrade / Grade Inspection Report Before Laying Fill Material Asphalt Concrete Placement
Structural Field inspection: Check on formation level before structural concrete delivery/placement formation
grade status, slope - polyethylene sheet - formwork & vertical and horizontal levels - embedment, joints
chamfer, mesh etc. Inspection Report Before Structural Concrete Pouring and Grout Placement
Metal sheet & Frame siding wall and Checking, Alinements, Before installation’s
Control subcontractor activities performed site according to method Statements, Quality Control procedures.
Monitors the works. of the contractors based on the specifications
Witness fresh concrete sampling pouring. Checks slump, air content Air temperature before casting Concrete.
Quality Control work Inspection check Team staff. And subcontractors
Check BOQ Price estimate, Disburesment of money Inspection Material Receive, be-fore Installation
Inspection Pile driving works, Prestressed Concrete pile, Bored pile Inspection Static pile load Test,
Dynamic Load Test, Seismic Test.
Check pouring concrete Before and After complete concrete Volume
Steel structure Work. Roof truss, Civil & Building Construction works.